National Food Safety Standard Determination of Glyceryl Monocrylate in Foods (English Version)
This standard specifies the gas chromatography and gas chromatography-mass spectrometry determination methods for monocaprylin in foods. It is applicable to the determination in raw wet noodle products, bean fillings, cakes, baked foods, beverages and surface hanging paddles (only bean fillings), meat sausages, algae strips and other foods.
Detection method | Scope of application | Reagent requirements | Instruments and equipment | Qualitative and quantitative methods |
---|---|---|---|---|
Gas chromatography (GC) | Raw wet noodle products, bean fillings, cakes, etc. | Chromatographic pure reagents, first-grade water | GC with FID detector | Qualitative by retention time, quantitative by external standard method |
Gas chromatography-mass spectrometry (GC-MS) | Bean fillings, cakes, meat sausages, etc. | Same as GC method, equipped with electron bombardment ion source | GC-MS with SIM mode | Qualitative analysis by SIM monitoring ions, quantitative analysis by external standard method |
With the increasingly stringent food safety supervision, the demand for detection of monocaprylin, as an important component of food additives, continues to increase. This standard combines the latest gas chromatography and mass spectrometry technologies to optimize the extraction, cleanup and determination processes to ensure the accuracy and reliability of the results.
Compared with the old version of the standard, the 2023 revised version introduces a gel permeation chromatography (GPC) cleanup step, which significantly improves the detection sensitivity, and achieves more accurate qualitative analysis through selected ion monitoring mode (SIM).