Technical requirements and test specifications for wireless power supply system of three-dimensional parking garage (English Version)
With the acceleration of urbanization, parking space resources are becoming increasingly scarce, and multi-story parking garages have been widely used as an efficient solution. As an important innovation in the field of electric vehicle charging, wireless power supply technology is of great significance in multi-story parking garages.
Category | MF-WPS1 | MF-WPS2 | MF-WPS3 | MF-WPS4 | MF-WPS5 | MF-WPS6 | MF-WPS7 |
---|---|---|---|---|---|---|---|
Power (P)/kW | P≤3.3 | 3.3
| 6.6
| 10
| 20
| (omitted) | P>60 |
System protection level:The protection level of the wireless power supply system should at least meet IP54 to ensure stable operation in harsh environments.
Insulation strength requirements:The system insulation resistance and dielectric strength must comply with GB/T38775.1-2020 standards to ensure electrical safety.
Rated working state:The system efficiency is not less than 85%, and the efficiency is not less than 82% under the allowable offset state.
Operating frequency range:It must comply with the "Radio Frequency Division Regulations of the People's Republic of China" and the requirements of the International Telecommunication Union to ensure electromagnetic compatibility.
In actual application, the MF-WPS4 power level (10