Verification and calibration of force standard machines (English Version)
As the core tool of measurement and calibration equipment, the accuracy and reliability of force standard machines are directly related to the quality of measurement results. GB/T 36412—2018 "Inspection and calibration of force standard machines" is based on the general technical requirements for testing machines (GB/T 2611) and the relevant specifications of the Machinery Industry Federation, combined with the development of advanced technologies at home and abroad, and comprehensively stipulates the technical requirements, inspection methods and calibration processes of force standard machines. This standard is applicable to deadweight, lever, hydraulic and superposition force standard machines to ensure their performance stability and measurement accuracy in different application scenarios.
Types of force standard machines | Technical requirements dimensions | Main technical indicators | Applicable scenarios |
---|---|---|---|
Static gravity force standard machine | Accuracy level and error range | ±0.01% (0.01 grade), ±0.03% (0.03 grade) Relative error of force value | High-precision calibration, static force measurement |
Lever type force standard machine | Amplification ratio error and discrimination force threshold | ±0.01% (0.03 grade), ±0.02% (maximum force) Discrimination threshold | Dynamic force testing, medium precision requirements |
Hydraulic force standard machine | Working pressure and cylinder plug system performance | ±0.03% (0.05 grade), ±0.1% (maximum force) Relative error | High dynamic range testing, large tonnage calibration |
Superposition force standard machine | Modular combination and repeatability | ±0.03% (0.1 grade), Force value fluctuation does not exceed 0.01% | Multi-purpose calibration, complex system integration |
In actual applications, the key technical parameters of force standard machines include amplification ratio error, discrimination force threshold and relative force error. For example, in a lever-type force standard machine, the maximum allowable value of the amplification ratio error is ±0.01%, while the maximum allowable value of the amplification ratio error of a hydraulic force standard machine is ±0.03%. These parameters directly affect the accuracy and repeatability of the measurement results.
GB/T 36412—2018 "Inspection and Calibration of Force Standard Machines" provides comprehensive technical specifications and implementation guidelines for the design, manufacture and application of force standard machines. By strictly following this standard, the accuracy and reliability of the measurement system can be ensured and the quality of experimental data can be improved.
It is recommended that practitioners in related industries regularly participate in professional training, familiarize themselves with the content of the standard, and optimize the inspection and calibration process in combination with actual application scenarios.