Printed circuit board draw (English Version)
Standard Dimensions | Technical Requirements | Implementation Suggestions | Comparative Analysis |
---|---|---|---|
Annotation Method | The dimension line method, grid method and hybrid method are used in combination to ensure the accuracy and clarity of dimensioning. | The dimension line method is preferred, the grid method is used for complex structures, and the hybrid method is suitable for multi-layer board design. | Compared with the old standard, the specific requirements of the grid method and hybrid method are added, and the annotation flexibility is significantly improved. |
Conductive graphics | Draw with double-line outline or coloring method, and indicate the dimension data such as wire width and spacing; large-area conductive areas and isolation areas need to be specially marked. | Choose the appropriate drawing method according to the complexity of the board layer; ensure that the marking of key dimensions meets the manufacturing tolerance requirements. | New requirements for the inner isolation area and isolation plate of multi-layer boards have been added, further improving the standardization of graphic drawing. |
Solder mask graphics | The size of the solder mask pad needs to consider parameters such as aperture and ring width; the shape of the pad is selected according to the wiring density to ensure that the risk of short circuit is avoided. | High-density design gives priority to round or square pads; special-shaped holes and special packaging devices require customized processing. | The simple solder mask pattern in the old standard has been refined, and a variety of shapes and calculation formulas have been added to meet the needs of modern manufacturing. |
Grid Method: Dimensioning is done by using rectangular coordinates or polar coordinates, which is suitable for dimensioning complex printed circuit board graphics. For example, in multi-layer board design, the grid method can more clearly express the relative position relationship between layers.
Solder Mask Pattern: A key structure used to prevent short circuits between wires. In practical applications, high-density wiring areas usually use cut circular or elliptical pads to optimize space utilization and reduce welding risks.
Via Position Drawing: A drawing method that includes circular holes and special-shaped holes. For example, in drilling manufacturing, special-shaped holes need to be accurately marked with six parameter values to ensure processing accuracy and position accuracy.
1. Design stage:
2. Manufacturing stage:
3. Inspection stage:
Copyright ©2007-2025 ANTPEDIA, All Rights Reserved