- Standard No.
- GB/T 24789-2022
- Language
- Chinese, Available in English version
- Release Date
- 2022
- Published By
- General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
- Latest
-
GB/T 24789-2022
- Replace
-
GB 24789-2009
- Scope
- This document specifies the general rules for the allocation and management of water measuring instruments for water use units, the requirements for the scope of measurement and the allocation rate of measuring instruments, and the requirements for measurement management. This document is applicable to the allocation and management of water measuring instruments for agricultural, industrial and service water units.
- Introduction
Technical points of standard revision
The technical update highlights of this version compared with GB24789-2009 are: - Added agricultural irrigation channel metering standards (main/branch/ditch need to be metered separately)
- Clarified the sub-item metering requirements for multiple buildings in the service industry (including heating/swimming pool/artificial snowmaking system)
- Upgraded intelligent requirements (emphasizing remote transmission and online calibration functions)
Comparison table of metering facilities for the three industries | Item | Industrial water use unit | Agricultural irrigation area | Service industry institution |
| Graded metering depth | Three-level configuration (unit→water-using equipment>1m³/h) | Four-level division (headwork→branch→output port) | Three-zone control (unit→functional area→equipment) |
| Equipment rate requirements | Main system<b>≥85% | Trunk and branch channel nodes<b>≥90% | Functional area nodes<b>≥95% |
Special instrument selection requirements
- Electromagnetic flowmeter(JJG1033)
- Applicable to places where the water quality of the main pipeline in the factory is stable, and annual mandatory inspection is required
- Ultrasonic water meter(JJG1030)
- Recommended for use when suspended solids exceed the standard in mining areas, monthly calibration is required
Intelligent management system solution
- Remote meter reading module: RS-485/4G gateway integration
- Data analysis platform: Water balance dynamic monitoring algorithm
- Abnormal early warning mechanism (Pipeline leakage identification model)
Application case: Power plant renovation project
The boiler system with a construction area of 300,000 square meters is configured with an intelligent control type
turbine flowmeter:
| Parameters | Before renovation | After renovation |
| Metering rate deviation | 7.2% | ≤0.5% |
| Annual water-saving economic benefits | - | ¥2.58 million |
GB/T 24789-2022 Referenced Document
- GB/T 21303 Specifications for water measurement of irrigation canal system
- GB/T 21534 Water saving—Terminology
- GB/T 778.1 Meters for cold potable water and hot water.Part 1: Metrological requirements and technical requirements
- JJG 1030 Technical performance test specification for constant temperature bath
- JJG 1033 Electromagnetic Flowmeters
GB/T 24789-2022 history
- 2022 GB/T 24789-2022 General rules for equipping and managing of the water measuring instrument in water-use organization
- 2009 GB 24789-2009 General provisions on equipping and managing of the measuring instrument of water in organization of water using
GB/T 24789-2022 General rules for equipping and managing of the water measuring instrument in water-use organization has been changed from GB 24789-2009 General provisions on equipping and managing of the measuring instrument of water in organization of water using.